RFI No. 15 Schoolname

Section 5 – FINISHING Subsection : 5.2 Lettering Question According to section 5.2 of the rules and regulations, if the complete name of the college or university is 31 characters or more (including all letters and spaces between words), the name may be...

RFI No. 12 Assembly of floating materials

Section 4 – Reinforcement Subsection : 4.2.5 Floating Materials Question Flotation material shall be solid blocks of material. Is the use of extruded polystyrene foam glued together in layers compliant with this? Answer You can use this as floatation material....

RFI No. 11 Aggregate proportioning

Section 3 – CONCRETE Subsection : 3.3.3 Aggregate proportioning Question On the data sheet for our ASTM C330 aggregate, it states percent passing the No. 200 sieve. To confirm, can teams use the percentage stated on the MTDS for the mix table calculations and sample...

RFI No. 10 – Filler content in aggregates

Section 3 – CONCRETE Subsection : 3.3.3. Aggregate Proportionning Question J’ai contacté la compagnie qui fourni le poraver afin de savoir la quantité de passant 75 microns pour le 0.25-1 mm et le 1-2 mm. La réponse a été qu’ils ne peuvent seulement...